WORKINGS back to cruquius home page
introduction | engines | sites | engineers | foundries | information

 

engine index E-0001
site index S-0001
 
worked from 1846 7 to 1862
 
engineer T.Wicksteed
pump size 33
lift
boiler number 6
boiler capacity
steam pressure 40
speed 8
duty 72
notes
KMB Kew Bridge museum booklet, JTS#7p27ff, BEH. Pumping against 235' head, initially the speed was 9.5 spm which was found to be excessive. Contract stipulated duty 77m per bushel Newcastle small best quality, achieved duty fell slightly short of this.

 